Interface Fan

Represents a ventilation component in the building that is not a HRV/ERV and is not attached to the mechanical system.

For EnerGuide: Depending on the whole_house status the fan gets categorized under the ventilation and influences the ventilation heat loss. For F280: Takes part in the AIM2 model in conjunction with the main ventilation, HRV/ERV, and air leakage.

interface Fan {
    auto_power: boolean;
    comment?: string;
    exhaust_ls: number;
    supply_ls: number;
    type: "Range hood" | "Bathroom" | "Utility" | "Dryer";
    whole_house: boolean;
}

Properties

auto_power: boolean

Denotes whether the fan can turn on automatically. Currently for documentation only.

comment?: string

See Comment.

exhaust_ls: number

Fan exhaust rate in liters per second. Can be a positive number or zero.

supply_ls: number

Fan supply rate in liters per second. Can be a positive number or zero.

type: "Range hood" | "Bathroom" | "Utility" | "Dryer"

Type of the fan. Gets used in the infiltration model to determine energy exchange due to ventilation.

For EnerGuide: At least one Dryer type must be present at all times.

whole_house: boolean

Determines the role of the fan. Fans that are not whole house systems may get ignored.